CytoFLEX LX Flow Cytometer

The CytoFLEX LX Flow Cytometer is an expansion of the CytoFLEX Platform. This model expands research possibilities with up to six lasers and 21 color parameters. Six spatially separated lasers allows panels to be spread across the spectrum reducing cross talk and spectral overlap.

  • Two series are available, UV-Violet-blue-Yellow Green-Red-IR (U-V-B-Y-R-I) and Near UV-Violet-Blue-Yellow Green-Red-IR (N-V-B-Y-R-I)
  • Instruments with as few as four activated laser and 14 color parameters are available with the option to activate additional lasers and colors in the future with the purchase of an activation key
  • For higher throughput applications an optional plate loader module is available and for use in regulated environments the software contains tools for 21 CFR Part 11 compliance

Choose a Model

Part Number Product Name Regulatory Status Lasers Number of Parameters Listenpreis Kaufen
RUO
355 nm, 405 nm, 488 nm, 561 nm, 638 nm
19 fluorescence detectors

-

RUO
355 nm, 405 nm, 488 nm, 638 nm
14 fluorescence detectors

-

RUO
355 nm, 405 nm, 488 nm, 561 nm
16 fluorescence detectors

-

RUO
355 nm, 405 nm, 488 nm, 561 nm, 638 nm, 808 nm
21 fluorescence detectors

-

RUO
375 nm, 405 nm, 488 nm, 561 nm, 638 nm, 808 nm
21 fluorescence detectors

-

RUO
375 nm, 405 nm, 488 nm, 561 nm, 638 nm
19 fluorescence detectors

-

RUO
405 nm, 488 nm, 561 nm, 638 nm
16 fluorescence detectors

-

RUO
405 nm, 488 nm, 561 nm, 638 nm
16 fluorescence detectors

-

Features

Exquisite Sensitivity

Platform Versatility

Low Maintenance

Automation Enabled

  • Optional 96-well plate sample loader
  • API (Application Programming Interface) allows external software to control the instrument
  • For automated sample processing and data acquisition integrate with the Biomek i-Series Instrument

Product Specifications

Detection Photodiodes
Resolution <300 nm particles (488 nm side scatter), <80 nm polystyrene particles (405 nm side scatter), rCV 3%
Performance <30 MESF for FITC, <10 MESF for PE
Flow Cell Patent-pending, alignment-free integrated optics quartz flow cell (420 μm x 180 μm ID) design with >1.3 numerical aperture
Signal Processing Digital system with 7-decade display
Power Requirements 100-240 VAC, 50/60 Hz
Item Specifications Referenced C00445

Documentation

  • Filter by:
Title Description
{B14306BD-BB46-4B27-BF3E-B11862085BC7}
{749D68FB-4893-4B2D-BD6C-C662F0520F64}
{749D68FB-4893-4B2D-BD6C-C662F0520F64}
{749D68FB-4893-4B2D-BD6C-C662F0520F64}
{A0D0EF0B-43F2-431C-BEB0-69F98765BDC4}
{9E29D7A5-B5EC-470A-A5C1-4EF9BFAE9959}
{9E29D7A5-B5EC-470A-A5C1-4EF9BFAE9959}
{B14306BD-BB46-4B27-BF3E-B11862085BC7}
{B14306BD-BB46-4B27-BF3E-B11862085BC7}
{A7DF4F56-8AF9-4BF1-88BE-766AB73FBC6B}
{442DF88C-CA7F-4B78-AF75-9D2B985534C0}|{279C6CA2-9797-4CFE-9CAA-5EAFAC29B60D}|{749D68FB-4893-4B2D-BD6C-C662F0520F64}

Technische Dokumente